Moving a fleet from one hosting provider to another in a single wave is simple to plan and expensive to execute. Every machine goes dark at the same moment and stays dark through decommissioning, packing, transit, receiving, racking and troubleshooting at the new site. For a large fleet that window can stretch to weeks, and the hashrate lost in it never comes back. A staged cutover trades a short period of paying two hosts for continuity of production, and for most operators that trade is worth making.
This is the production side of a move. The physical side, getting machines off racks, counted, packed and onto a truck in good order, is covered in our guide to moving miners out when a hosting agreement ends. What follows assumes that part is handled well and asks a different question: how do you sequence the move so the fleet keeps earning while it happens?
What dark time actually costs
The cost of a machine sitting idle is easy to state and easy to underestimate. Each day offline forfeits that machine’s share of the network reward at the prevailing hashprice. Multiply by the number of machines and the number of days and the total can be large, but it is the shape of the loss that matters most.
Mining revenue is not deferred, it is forfeited. The network does not hold your share of blocks until you return. It keeps producing them roughly every ten minutes and distributes the rewards to whoever is hashing. The protocol recalculates difficulty every 2,016 blocks, roughly every two weeks, based on the hashrate actually observed, so a fleet that comes back online after a long outage simply rejoins whatever conditions prevail at that point. There is no catching up.
That is the case for staging. Every machine that keeps running while the others are in transit is revenue that a single-wave move would have discarded.
Why single-wave moves run long
The transit itself is usually the most predictable part. The delays come from the receiving end, and they are almost always discovered only when the whole fleet is already sitting on the new site’s dock.
- Power not energized at the rack. Capacity that exists on the site’s single-line diagram is not the same as circuits that are live at the positions assigned to you.
- Receptacle and cord mismatches. A difference in plug type, voltage or phase configuration between the old site and the new one can leave a pallet of machines unconnectable until parts arrive.
- Network and configuration. New IP ranges, firewall rules and management access all need to work before a single unit can be pointed at a pool.
- Damage in transit. Hashboards and fans do not always survive a truck journey, and failures that appear only under load are discovered only once power is on.
- Intake processing time. A professional site will inspect, count and record every unit on arrival. That is good practice, and it takes time that scales with the size of the delivery. Our guide to receiving inspection at a hosting site explains what that process involves.
In a single-wave move, any one of these stops the entire fleet. In a staged move, it stops one wave, and you discover it while most of the fleet is still earning at the old site.
Start with a pilot wave
The first wave should be small and its purpose is diagnostic. It proves that the receiving site is genuinely ready: that circuits are live, cords fit, the network works, pool configuration is correct and intake runs smoothly. Every problem the pilot finds is a problem the remaining fleet avoids.
Choose machines for the pilot deliberately. Include at least one unit of every model you are moving, so that any model-specific power or configuration issue surfaces early. Do not send your oldest or least reliable units, because a failure in the pilot should tell you about the site rather than about the hardware.
Run the pilot wave at full load for long enough to see stable behavior before scheduling the next one. Hashrate, temperatures and reject rates should look the way they did at the old site. If they do not, you have learned something important at the lowest possible cost.
Size the remaining waves to the receiving site’s capacity
After the pilot, wave size is governed by how much the receiving site can intake, rack and bring online in a given period, not by how much fits on a truck. Ask the new host how many units its team can process per day and plan waves that fit inside that number with some slack. A wave that exceeds intake capacity simply waits on the dock, which is the same dark time you were trying to avoid.
Each wave should be reconciled against your records before the next ships. Serial numbers out of the old site should match serial numbers into the new one, with any discrepancy resolved immediately rather than at the end. A maintained asset register for the hosted fleet turns this from a forensic exercise into a checklist.
The overlap period, and how to pay less for it
Staging means that for some period you are paying both hosts. That cost is the price of continuity, and it is worth negotiating on both sides rather than simply accepting.
At the old site, the question is whether your agreement allows capacity to be released progressively as machines leave, or whether you pay for the full commitment until the end of the term. A ramp-down is worth asking for well in advance, and the considerations involved when a hosting term comes to an end apply directly here.
At the new site, ask for a ramp-up schedule that matches your wave plan, so you are billed for capacity as it is actually used rather than for the full commitment from day one. Minimum consumption commitments that start before the fleet arrives are a common and avoidable overlap cost, and they are exactly the kind of charge that sits outside the headline rate. Our breakdown of what a hosting rate actually contains is a useful reference when comparing those terms.
Keep pool and monitoring continuity through the move
A migration is the easiest time to lose visibility of your fleet. Machines change IP addresses, management access changes, and dashboards that were built around the old site’s network stop showing accurate numbers.
- Keep worker names stable, or adopt a naming convention that identifies the site, so pool statistics remain readable throughout.
- Consider a separate pool sub-account per site for the duration of the move, so you can see each site’s hashrate independently and confirm that each wave came online as expected.
- Confirm payout addresses on every machine in each wave before it ships. A configuration error that sends a batch’s earnings somewhere unintended is easy to make during a busy migration.
- Record baseline performance for each machine before it leaves, so post-move comparisons are meaningful.
Transit risk is yours unless you arrange otherwise
It is easy to assume that a carrier is responsible for anything damaged on its truck. In the United States, interstate carrier liability is governed by a federal framework, and the liability of carriers under bills of lading can be limited by the terms of the shipment. A low declared value on the paperwork can cap what you recover at a small fraction of what the machines are actually worth.
Declare an accurate value, understand what the carrier’s terms actually cover, and check whether your own equipment insurance covers goods in transit between sites, since many policies treat that differently from equipment at rest in a facility. The ASIC shipping and logistics guide covers packing and carrier selection, and the article on who pays when hosted miners are damaged explains the evidence you need if something arrives broken. Photograph every pallet before it leaves and as it arrives.
A simple sequence
Every move is different, but a workable plan usually runs in this order.
- Agree the ramp-down at the old site and the ramp-up at the new one, in writing, before anything moves.
- Confirm with the receiving site that circuits are live at your assigned positions, receptacles match, and network access is configured.
- Record baseline performance and reconcile the asset register.
- Ship a small pilot wave covering every model, and run it at full load until behavior is stable.
- Fix anything the pilot found, then ship the remaining fleet in waves sized to the receiving site’s intake capacity.
- Reconcile serials and confirm hashrate for each wave before the next one ships.
- Release capacity at the old site as each wave leaves, and close out the old agreement once the last unit is confirmed online at the new one.
The result is a move that takes somewhat longer on the calendar and costs far less in lost production. The fleet spends most of the migration earning, problems are found while they affect a handful of machines rather than all of them, and the final wave arrives at a site that has already proven it can bring your hardware online.