Your miners sit in someone else’s building as bailed property. Which clauses decide whether the host pays, how your own policy differs, and the evidence a claim needs before the loss happens.

A hosted S21 comes back from a power event with two dead hashboards. The host says the utility caused it and points at the force majeure clause. Your insurer asks who had custody of the machine. Both are really asking the same question, and the hosting agreement answered it months ago in a paragraph nobody read at signing. Whether that repair comes out of the host’s pocket, your policy, or your own cash flow is decided long before the board fails — and the evidence that decides it has to exist before the loss, not after.

This is a narrower question than which policy to buy. Coverage types, limits and premiums are the shopping decision. This is what happens after something breaks: who is legally on the hook while your hardware sits in someone else’s building, and what a claim actually requires from you.

Your miners are bailed property, and that is the whole foundation

When you ship machines to a host, you keep ownership and hand over possession. The legal term for that arrangement is bailment, and it is the reason a host cannot simply shrug when your hardware is damaged on their floor. A bailee holding goods for the mutual benefit of both parties owes a duty of reasonable care. Not a guarantee — reasonable care. The host is not an insurer of your equipment, but neither are they a bystander.

The closest statutory analogue is the warehouse. Under UCC §7-204, a warehouse is liable for damages caused by its failure to exercise the care a reasonably careful person would exercise in the same circumstances, and is not liable for damage that could not have been avoided by that care. The same section lets the warehouse contractually limit its liability to a stated amount per item. That second half is what your hosting agreement is doing when it caps liability at, say, three months of hosting fees or the depreciated value of the unit.

So the ceiling on what you can recover from the host is usually not set by law. It is set by the limitation-of-liability clause you signed, and that clause is negotiable at signing and immovable afterwards.

Read the three clauses that decide the outcome

Before any loss, find these in your agreement and write down what they say:

  • Limitation of liability. Is there a cap, and is it a dollar figure, a multiple of monthly fees, or the depreciated equipment value? Does it exclude consequential damages — which is where your lost mining revenue lives?
  • Force majeure. What counts? A grid event, a utility curtailment and a storm are three different things, and a broadly drafted clause can absorb all of them. Note whether the clause merely suspends the host’s performance obligation or also extinguishes liability for damage that occurs during the event.
  • Insurance obligations. Does the host carry property coverage, and does it cover customer-owned equipment or only their own building and infrastructure? Those are very different policies. Many hosts carry the second and let clients assume it is the first.

The broader contract read-through covers these as line items. The point here is that in a claim they operate together: force majeure decides whether the host is responsible at all, the liability cap decides the maximum if they are, and the insurance clause decides whether there is a policy behind that number or just a balance sheet.

Two policies, and the gap between them

In a well-structured hosted arrangement there are two insurance programs in play. The host carries commercial property and general liability for the facility. You carry equipment coverage on machines you own, wherever they sit. Neither is a substitute for the other, and the common failure is assuming one covers what the other does.

The host’s policy protects the host. If their negligence damaged your machines, their liability coverage may respond — to their limits, subject to their deductible, on their timeline, and only after fault is established. Your own equipment policy responds to damage to your property without requiring you to prove anyone was at fault first. That difference matters more than the premium.

If your insurer pays you and the host was genuinely responsible, the insurer then steps into your shoes and pursues the host directly. That right is called subrogation, and it has a practical consequence worth flagging: a waiver-of-subrogation clause in your hosting agreement, which hosts frequently request, removes your insurer’s ability to recover from the host. Insurers price that. Some will decline the risk or charge for the endorsement. Do not agree to a subrogation waiver without telling your broker, because it can quietly affect whether your own policy responds the way you expect.

The evidence has to exist before the loss

Every claim, under either policy, turns on two things you cannot reconstruct after the fact: that the machine was yours, and that it was working before the event.

Ownership is the easier half. Keep purchase invoices tied to serial numbers, the shipping manifest, and the host’s signed receiving record. A maintained asset register for the hosted fleet is the document that makes this a five-minute exercise instead of a forensic one.

Performance baseline is the half that gets skipped. An adjuster asking what the unit was producing before the event will not accept a nameplate figure. What answers it is per-serial hashrate and uptime history from your own pool and monitoring data, retained long enough to cover a claim window. If the only record of your fleet’s output lives in the host’s dashboard, and the dispute is with the host, you have a problem that is purely procedural and entirely avoidable: export it yourself, on a schedule.

Two more things, both cheap and both frequently missing. Photograph units at intake, including serial plates and any existing cosmetic damage. And keep the environmental record — inlet temperatures and humidity at your racks — because the most common host defence to a hashboard claim is that the failure was heat-related and gradual rather than caused by a single event. Without your own environmental data you are arguing against the host’s data.

What to do in the first week after a loss

Notice periods are short and are a real basis for denial. Work in this order.

Notify both your insurer and the host in writing immediately, before you know whose problem it is. Late notice prejudices a claim; notifying two parties and later withdrawing one costs nothing. Ask the host to preserve the failed hardware and not return, repair or dispose of it, because the physical unit is evidence and a repaired board cannot be inspected. Request the host’s own records for the window: power quality logs, any alarm history, the maintenance log for that row, and the incident report if one exists. Capture your own data for the same window before the retention period rolls over. Then put the sequence of events in one dated document while the detail is fresh.

If the host’s contract gives you an audit or inspection right, this is the situation it was negotiated for. If it does not, you are reliant on what the host volunteers.

What to fix at signing, not at claim time

Everything above is cheaper to arrange before anything breaks. Three things are worth real negotiating effort. Ask for a certificate of insurance naming the host’s property and liability coverage, and check whether customer equipment is a covered interest rather than taking it on description. Push back on a liability cap that is lower than the value of the hardware you are placing, or at minimum carve equipment damage out of the general cap. And if you are asked for a waiver of subrogation, price it with your broker first.

None of this assumes bad faith. Most hosts handle damage honestly, and a good one will have logs ready before you ask. The reason to set it up in advance is that the moment you need these documents is precisely the moment your interests and your host’s have diverged, and the terms are already fixed. Hosting with a provider that keeps per-rack environmental and power-quality records as a matter of course, and will share them, removes most of this problem before it starts — which is a reasonable question to ask on a site visit rather than after a failure.